1008 Milk Investigation, Fat Determination Article Order No. For butyrometers according to Van Gulik‘s method. l3 = 66 mm l2 = 38 mm l1 = 27,8 mm d2 = 15 mm d1 = 5 mm Weighing boats for butter 10 42 03322 For butyrometer according to Roeder‘s method. l3 = 75 mm l2 = 45 mm l1 = 30 mm d2 = 15 mm d1 = 5 mm Butter beaker with 2 holes 10 42 03323 l3 = 75 mm l2 = 48 mm l1 = 27 mm d2 = 15 mm d1 = 5 mm Babcock bottle, 0-8% for milk, without stopper 10 42 03254 Stopper on request. 163 mm length, outer-Ø 35.8 mm. Babcock bottle, 0-20% for cream, without stopper 10 42 03256 163 mm length, outer-Ø 36.2 mm Babcock bottle, 0-60% for cream and cheese, without stopper 10 42 03258 164 mm length, outer-Ø 35.9 mm Extraction tube with rounded bulb 10 42 03870 according to Mojonnier, ISO 3889, with cork stopper Extraction tube with flattened bulb 10 42 03871 according to Mojonnier, with cork stopper Cork stopper for extraction tube 10 42 03872 according to Mojonnier, ISO 3889 Solubility index tube (ADPI tube) 10 42 03634 50 ml, graduated from 0–20 ml and mark at 50 ml. For the centrifuge SuperVario-N. Special solubility index tube 10 42 03637 For determining the solubility of milk powder. For the bench centrifuge NovaSafety. webcode WW39Q002 Mojonnier Agitator, Aerne Analytic Used for determining the fat content of milk. Material white PVC, digital display, operated by an induction motor Customised versions (also for other contents / vessels) available on request. Type Specification Power rating W Order No. MSM 4 Mojonnier agitator for 4 Mojonnier tubes 60 10 64 01040 MSM 6 Mojonnier agitator for 6 Mojonnier tubes 60 10 64 01060 MSM 8 Mojonnier agitator for 8 Mojonnier tubes 60 10 64 01080 Centrifuges for Determination of Fat, Funke - Dr. N. Gerber Nova Safety Centrifuge Bench centrifuge with angular rotor for butyrometric fat determination according to Dr. N. Gerber, as well as for the determination of the solubility of milk powder with special solubility index tubes (art. no.: 3637). Properties: • Automatic interlocking lid • Automatic brake (braking time < 8 s) • Centrifugation timer (digital) • Heater: temperature adjustable in 1°C steps from room temperature up to 65°C (can be switched off) • Capacity: max. 8 butyrometers or max. 8 special solubility index tubes Technical data: RCF: 350 g ±50 g Speed: 1350 rpm Effective radius: 170 mm Weight: 13 kg Dimensions (W×D×H): 470 × 380 × 230 mm Power supply: 230 V / 50 – 60 Hz Article Order No. Table centrifuge Nova Safety 55 42 03670 Replacement tube for butyrometer 10 42 03641 Special Analysis Food, Feedstuffs, Drugs
RkJQdWJsaXNoZXIy MTIxNDc3OQ==