To see other variants and accessories, please enter the webcode on our website. webcode 297 2 1Horizontal Floor-standing Autoclaves, Systec H-Series Specially designed for the requirements in laboratories, these autoclaves make sterilization processes safe, accurate, reproducible and validatable. Autoclaves of the performance category HX can be used for all laboratory applications, even for sophisticated sterilization processes. All additional optional accessories can be fitted to obtain validatable processes. In spite of the high loading capacity, these autoclaves are compact and have a comparatively low weight. Type Useful space Ø × depth mm Useful volume total / nominal l H × W × D mm Net weight kg Order No. HX-65 400×500 70 / 65 1610×704×865 220 10 12 92212 HX-90 400×750 105 / 90 1610×704×1065 300 10 12 92213 HX-100 500×500 115 / 100 1710×804×900 350 10 12 92214 HX-150 500×750 165 / 150 1710×804×1150 400 10 12 92215 HX-200 500×1000 215 / 200 1710×804×1400 450 10 12 92216 HX-210 740×500 280 / 210 1865×944×980 600 10 12 92220 HX-320 740×750 385 / 320 1865×944×1230 670 10 12 92230 HX-430 740×1000 495 / 430 1865×944×1480 740 10 12 92240 HX-540 740×1250 600 / 540 1865×944×1730 810 10 12 92250 HX-650 740×1500 710 / 650 1865×944×1980 880 10 12 92260 HX-580 1000×750 750 / 580 2025×1269×1340 950 10 12 92270 HX-780 1000×1000 930 / 780 2025×1269×1590 1050 10 12 92280 HX-980 1000×1250 1130 / 980 2025×1269×1840 1150 10 12 92290 HX-1180 1000×1500 1325 / 1180 2025×1269×2090 1250 10 12 92300 HX-1380 1000×1750 1520 / 1380 2025×1269×2340 1350 10 12 92310 HX-1580 1000×2000 1715 / 1580 2025×1269×2590 1450 10 12 92320 Electrical connections for the Systec HX-65 to HX-200: 380 – 400 V, 50 / 60 Hz, 16 A. Electrical connections for the Systec HX-210 to HX-1580: 380 – 400 V, 50 / 60 Hz, 32 A. Different voltage available upon request. Country-specific deviations are possible. 2Horizontal Pass-through Autoclaves, Systec H-Series 2D Triple safety aspects • One door only can be opened at a time. If one door is open, the other is automatically locked. • If the autoclave is switched off or if no current is available (e.g. power failure), both doors remain locked. • If the door at the non-sterile side is opened, a sterilization program hast o be performed before the door at the sterile side can be opened. The locking system can be adapted to customers’ wishes. Doors and control panel are made of heat-insulating plastic, the housing completely of stainless steel and the stainless steel edges specially processed for smooth junctions with walls. Operation, however, can be carried out from both sides, the position (open or closed) of the opposite door being indicated on the display. For use under the most stringent clean room and safety conditions • For biological safety laboratories. Fitting as a sterilization and pass-through lock for protecting the external environment. • For clean rooms in laboratories and production facilities as a sterilization and passthrough lock separating sterile and non-sterile areas. Steam Sterilizers Type Useful space Ø × depth mm Useful volume total / nominal l H × W × D mm Order No. HX-90 2D 400×750 100 / 90 1610×704×690 10 12 92096 HX-150 2D 500×750 160 / 150 1710×804×695 10 12 92156 HX-200 2D 500×1000 210 / 200 1710×804×950 10 12 92207 HX-320 2D 740×750 370 / 320 1865×944×740 10 12 92235 HX-430 2D 740×1000 480 / 430 1865×944×990 10 12 92245 HX-540 2D 740×1250 590 / 540 1865×944×1240 10 12 92255 HX-580 2D 740×1500 700 / 650 2025×1269×785 10 12 92271 HX-650 2D 1000×750 680 / 580 1865×944×1450 10 12 92265 HX-780 2D 1000×1000 880 / 780 2025×1269×1035 10 12 92275 HX-980 2D 1000×1250 1075 / 980 2025×1269×1285 10 12 92285 HX-1180 2D 1000×1500 1270 / 1180 2025×1269×1535 10 12 92295 HX-1380 2D 1000×1750 1465 / 1380 2025×1269×1785 10 12 92305 HX-1580 2D 1000×2000 1665 / 1580 2025×1269×2035 10 12 92315 Electrical connections for the Systec HX-90 2D to HX-200 2D: 380 – 400 V, 50 / 60 Hz, 16 A. Electrical connections for the Systec HX-320 2D to HX-1580 2D: 380 – 400 V, 50 / 60 Hz, 32 A. Different voltage available upon request. Country-specific deviations are possible. Safety, Cleaning, Hygiene Sterilization

RkJQdWJsaXNoZXIy MTIxNDc3OQ==