Continued on next page 502 • ltrasonic Homogenizers webcode WWFH8008 1 2 SONOPULS Ultrasonic Homogenizers, BANDELIN Selecting the best SONOPULS ultrasonic homogenizer for your needs The ultrasonic output of an homogenizer depends on the amplitude present at the ultrasound-emitting surface of the sonotrode. Start with the volume of the sample that is to be subjected to the ultrasound. Use the diameter of the ultrasound vessel into which the sonotrode is to be immersed and the following table to determine the optimum sonotrode amplitude and the correct SONOPULS ultrasonic homogenizer. Titanium sonotrodes in conjunction with the SONOPULS ultrasonic homogenizer Type Dia. HD 2070.2 HD 2200.2 Amplitude µmss mm HD 2070.2/2200.2 MS 72 2 1 ml – 25 ml 2 ml – 30 ml 285/286 MS 73 3 2 ml – 50 ml 5 ml – 90 ml 245/308 KE 76 6 5 ml – 100 ml 10 ml – 350 ml 191/255 TT 13 13 10 ml – 200 ml 20 ml – 900 ml 93/165 VS 70 T 97/170 TT 25 25 30 ml – 1000 ml - /53 Examples: 1 ml liquid in centrifuge vial with 9 mm ID: MS 73 microtip on HD 2070.2. 15 ml liquid in test tube with 12 mm ID: KE 76 conical tip on HD 2070.2. 100 ml liquid in glass beaker with 45 mm ID: TT 13 titanium disk on HD 2200.2. 10 ml sample volume in 50 ml Corning container for bacteria digestion with MS 73 in HD 2200.2 70 ml sample ground cheese in water in RZ 3 for HD 2200.2 with VS 70 T SONOPULS HD 2070.2 and HD 2200.2 Cell disintegration, accelerated reaction, extracting, emulsifying, suspending, homogenizing, degassing of liquids and for the Sonochemie. Controllable, high energy density for the processing and preparation of samples with ultrasound in the biochemistry lab, in research and in small-scale production. Amplitude adjustment with electronic stabilization in a range of 10 – 100% for consistent results. Pulsation of 10 – 100% limits the temperature increase when handling heat-sensitive samples. Cooling in pauses between sound pulses. 20 kHz equalized sound. Sound period 1 sec to 99 min. All values appear on the digital display. Proteced against dry-running and constant operation. 230 V (115 V also available). Article Order No. 1SONOPULS HD 2070.2 Ready-to-use set 10 07 32451 For volumes from 2 ml to 50 ml. Ready-to-use basic model: Ultrasonic generator GM 2070.2, ultrasonic transducer UW 2070, horn SH 70 G with external thread and microtip MS 73, dia. 3 mm. 70 W HF power. See table above for other volumes. Stand HG 40 and vessel RZ 2 shown in the illustration are not included in delivery. Article Order No. SONOPULS HD 2200.2 Ready-to-use set 10 07 32531 For volumes from 20 ml to 900 ml. Ready-to-use basic model: Ultrasonic generator GM 2200.2, ultrasonic transducer UW 2200, booster horn SH 213 G with external thread and titanium disk TT 13, dia. 13 mm. 200 W HF power. See table above for other volumes. Stand HG 40 and vessel RZ 2 shown in the illustration are not included in delivery. Accessories for HD 2070.2 and HD 2200.2 For connecting titanium sonotrodes: Titanium horns instead of SH 70 G/SH 213 G Article Order No. SH 219 G Ø 19 mm for UW 2200 53 07 02210 SH 225 G Ø 25 mm for UW 2200 53 07 02212 3 SONOPULS HD 4050 / 4100 / 4200 Technical data: HD 4050 HD 4100 HD 4200 HF generator: GM 4200 GM 4200 GM 4200 W × H × D (mm): 150×220×335 150×220×335 150×220×335 Ultrasonic converter: UW 50 UW 100 UW 200 Ø × L (mm): 45 × 175 70 × 150 70 × 150 Available sonotrodes Ø (mm): 2/ 3/ 4.5/ 6 2/ 3/ 4.5/ 6/ 9/ 13 3/ 4.5/ 6/ 9/ 13/ 16/ 25 Article Order No. Ultrasonic homogenizer SONOPULS HD 4050 10 07 34050 for volumes from 0.5 – 100 ml Ready-to-operate set: for volumes from 0.5 ml – 20 ml, ultrasonic power max. 50 W, ultrasonic generator GM 4200, ultrasonic converter UW 50, titanium probe TS 102, dia. 2 mm Ultrasonic homogenizer SONOPULS HD 4100 10 07 34100 for volumes from 2 – 200 ml Ready-to-operate set: for volumes from 3 – 50 ml, ultrasonic power max. 100 W, ultrasonic generator GM 4200, ultrasonic converter UW 100, standard horn SH 100 G, titanium probe TS 103, dia. 3 mm Sample Preparation Size Reduction
RkJQdWJsaXNoZXIy MTIxNDc3OQ==