Continued on next page 524 Extractors webcode WW6PB009 Extraction Thimbles, Hahnemühle Cellulose extraction thimbles For reliable and fast analysis in the areas of food control and environmental monitoring. Suitable for Soxhlet-type, Tecator-type or similar devices, to extract certain components out of solid material with an appropriate solvent. • Made of cellulose that is totally free from binding elements, with a minimum content of extractable components • High purity of selected cellulose guarantees reliable and replicable results • The consistent high porosity of the thimbles ensures a fast flow • High fitting accuracy for all available extraction systems Available for two device types: • Type 900: Soxhlet extraction, inner diameter measurement • Type 901: Tecator extraction, outer diameter measurement Technical data: Inner diameter Wall thickness Maximum Temperature <33 mm 1.3 mm 120°C >35 mm 1.7 mm 120°C Ø × H mm Order No. PU pc/Pack Ø × H mm Order No. PU pc/Pack 19 × 90 10 15 99001 25 33 × 80 10 15 99011 25 22 × 80 10 15 99002 25 33 × 90 10 15 99012 25 22 × 100 10 15 99030 25 33 × 94 10 15 99013 25 25 × 60 10 15 99003 25 33 × 100 10 15 99024 25 25 × 70 10 15 99032 25 33 × 118 10 15 99015 25 25 × 80 10 15 99005 25 33 × 130 10 15 99027 25 25 × 100 10 15 99006 25 33 × 205 10 15 99023 25 28 × 60 10 15 99035 25 35 × 150 10 15 99017 25 28 × 80 10 15 99026 25 40 × 100 10 15 99028 25 28 × 100 10 15 99007 25 40 × 123 10 15 99018 25 30 × 80 10 15 99008 25 40 × 150 10 15 99034 25 30 × 100 10 15 99009 25 43 × 123 10 15 99019 25 33 × 60 10 15 99010 25 26 (O.-Ø) × 60 10 15 99029 25 Other sizes on request. webcode WWW4U082 Solvent Extractors, LAT There are three good reasons for getting an extractor pursuant to Randall: • up to 5 times faster than Soxhlet extraction • less solvent consumption • low costs per analysis Furthermore, the SER 148 offer the user full compliance with IP55. The main field of application is the determination of the content of soluble products such as fats, softening agents, and pesticides in foods, animal feed, rubber and products made of synthetics, pharmaceutical products, soils, etc. Technical data: Maximum volume per jar: 150 ml Operating temperature: 100 to 260°C Sample volume: 0.5 – 15 g (usually 2–3 g) Solvent recovery: 50 – 75% Reproducibility: < 1% Interface: RS232 Type Power input W Dimensions mm Weight kg Order No. SER 148/3 500 W 480×620×390 30 10 20 11483 SER 148/6 950 W 700×620×390 40 10 20 11486 Sample Preparation Extraction
RkJQdWJsaXNoZXIy MTIxNDc3OQ==