Catálogo General de Material para Laboratorio

Continued on next page To see other variants and accessories, please enter the webcode on our website. webcode 537 Series FD: Drying chambers with forced convection Model Interior vol. l Outer W × H × D mm Inner W × H × D mm Order No. FD 56 60 560×625×565 400×440×345 10 40 10303 FD 115 116 710×735×605 550×550×385 10 40 10305 FD 260 259 810×965×760 650×780×515 10 40 10309 FD 720 741 1165×1590×870 1000×1300×570 10 40 10311 Safety Drying Ovens Series FED: Heating chambers with forced convection and enhanced timer functions Model Interior vol. l Outer W × H × D mm Inner W × H × D mm Order No. FED 56 60 560×625×565 400×440×345 10 40 10295 FED 115 116 710×735×605 550×550×385 10 40 10293 FED 260 259 810×965×760 650×780×515 10 40 10299 FED 720 741 1165×1590×870 1000×300×570 10 40 10301 You will find further model sizes in the Classic.Line Incubators, Cooled Incubators webcode WWW4U037 Drying Ovens, LAT Bench-top unit for incubating smeared or dipped slides or conventional petri dishes, incl. insert rack. • 25°C to 45°C • ±1°C • 220 V / 110 V / 12 V • 26 W • Protection class II • Thermometer in the unit • Plexiglas front panel • External W×H×D: 310 × 155 × 168 mm • Internal W×H×D: 220 × 120 × 150 mm Article Order No. Drying oven LATURA 41 80 50000 webcode WW91A002 Incubators, Memmert Incubators for research, medicine, pharmaceutics, and food technology. Organic material requires particularly gentle heating. For this reason, heating and control of these incubators have been optimised specifically for low temperatures of up to +80°C. To avoid overshoots, the temperature is increased within a very narrow range and maintained accurately at the setpoint value. • With large area all-round heating • Pre-heating of the fresh air • With interior glass door Medical product certification: Memmert Im incubators are class I. Until the entry into force of Regulation (EU) 2017/745 (MDR), Memmert Class I medical devices will be placed on the market in accordance with EU Directive 93/42 / EEC. After the regulation comes into force, Memmert will market Class I medical devices in accordance with MDR. In accordance with their intended use, Memmert Im incubators may be used for controlling the temperature of flushing and infusion solutions and contrast agents. All of the product information below also applies to the medical devices Im. IN and IF incubators N = Natural convection F = Forced air circulation 2 model variants: SingleDISPLAY and TwinDISPLAY (a detailed description of the two variants can be found on page 531) Technical data: Work temperature range: at least 5°C (UN), at least 10°C (UF) bove room temperature up to +80°C Set temperature range: +20°C up to +80°C Setting accuracy: 0.1°C Electrical supply: 230 V 50/60 Hz (other voltages to special order) Heating Units, Refrigerating Units Temperature Controllers

RkJQdWJsaXNoZXIy MTIxNDc3OQ==