Continued on next page 546 CO2 Incubators 1 2 3 4 Technical data: Working temperature range: at least. 5°C above ambient temperature up to +50°C. Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors) Setting temperature range: +18°C to +50°C Setting accuracy temperature: 0.1°C Setting range active humidity control: 40 to 97% rh and rh-Off Setting accuracy humidity: 0.5% rh Setting range CO2: 0 to 20% Setting range O2: 1 to 20% Setting accuracy CO2: 0.1% Setting accuracy O2: 0.1% Power supply: 230 V, 50/60 Hz (other voltages on request) Available models and sizes with heated inner glass door and outer fully insulated stainless steel door: Type series ICOmed Type Outer W×H×D mm Inner W×H×D mm Vol. approx. l Wght approx. kg P rating approx. W Order No. 1ICO50med 559×791×521 400×425×330 56 55 1000 10 26 09050 2ICO105med 719×850×591 560×480×400 107 75 1300 10 26 09105 3ICO150med 719×1070×591 560×700×400 156 90 1500 10 26 09150 4ICO240med 759×1180×691 600×810×500 241 110 1650 10 26 09240 External dimensions: depth without door handle (door handle depth 56 mm) Inner dimensions: depth minus 35 mm for fan Options for ICOmed models Battery-buffered ControlCOCKPIT Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameters even when there is a power failure. The CO2 parameter is continuously regulated. For all sizes. Article Order No. Battery-buffered ControlCOCKPIT 10 26 09302 Automatic switch-over of gas cylinders Two gas connections with quick release connectors. Suitable for all sizes. Article Order No. Automatic switch-over of gas cylinders 10 26 09301 Electropolished interior space Article Order No. for size 50 10 26 09401 for size 105 10 26 09402 for size 150 10 26 09403 for size 240 10 26 09404 Active microprocessor humidification and dehumidification control (40 – 97% rh) Including digital indication and auto-diagnostic system; ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with water (only use demineralized / fully demineralized water with a conductivity of 5 to 10 µS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter. For all sizes. Article Order No. Active microprocessor humidification and dehumidification control (40 – 97% rh) 10 26 09307 Control of oxygen concentration By introducing nitrogen, adjustment range from 1% to 20% O2, setting accuracy 0,1%. Requires active microprocessor control for humidifying and dehumidifying. Incl. N2 connection set: hose with connection coupling and hose clamp. Suitable for all sizes. Article Order No. Control of oxygen concentration 10 26 09306 Peltier cooling unit Allows for an operating temperature of 37°C also with higher environmental temperatures of up to 35°C. Article Order No. for size 50 10 26 09501 for size 105 10 26 09502 for size 150 10 26 09503 for size 240 10 26 09504 Heating Units, Refrigerating Units Temperature Controllers
RkJQdWJsaXNoZXIy MTIxNDc3OQ==