Catálogo General de Material para Laboratorio

Continued on next page 892 Areometers webcode WWE16001 1 2 3 Areometers without Thermometer, Gering Overall length approx. 280 mm, scale value 0.002 g/ml (20°C) Range Order No. Range Order No. 0.600 – 0.800 16 60 32001 1.400 – 1.600 16 60 32005 0.800 – 1.000 16 60 32002 1.600 – 1.800 16 60 32006 1.000 – 1.200 16 60 32003 1.800 – 2.000 16 60 32007 1.200 – 1.400 16 60 32004 Overall length approx. 160 mm, scale value 0.001 g/ml (20°C). Range Number Order No. Range Number Order No. 0.600 – 0.660 00 16 60 33001 1.300 – 1.360 11 16 60 33013 0.650 – 0.710 0 16 60 33002 1.360 – 1.420 12 16 60 33014 0.700 – 0.760 1 16 60 33003 1.420 – 1.480 13 16 60 33015 0.760 – 0.820 2 16 60 33004 1.480 – 1.540 14 16 60 33016 0.820 – 0.880 3 16 60 33005 1.540 – 1.600 15 16 60 33017 0.880 – 0.940 4 16 60 33006 1.600 – 1.660 16 16 60 33018 0.940 – 1.000 5 16 60 33007 1.660 – 1.720 17 16 60 33019 1.000 – 1.060 6 16 60 33008 1.720 – 1.780 18 16 60 33020 1.060 – 1.120 7 16 60 33009 11.780 – 1.840 19 16 60 33021 1.120 – 1.180 8 16 60 33010 1.840 – 1.900 20 16 60 33022 1.180 – 1.240 9 16 60 33011 1.900 – 1.960 21 16 60 33023 1.240 – 1.300 10 16 60 33012 1.960 – 2.020 22 16 60 33024 Complete set with locator in a case Overall length approx. 160 mm Article Order No. 224 areometers, range: 0.600 to 2.020 and locator 16 60 33500 Series M 100 Overall length ca. 245 mm, scale value 0.002 g/ml (20°C), calibratable. Range Order No. Range Order No. 0.600 – 0.700 16 60 34001 1.300 – 1.400 16 60 34008 0.700 – 0.800 16 60 34002 1.400 – 1.500 16 60 34009 0.800 – 0.900 16 60 34003 1.500 – 1.600 16 60 34010 0.900 – 1.000 16 60 34004 1.600 – 1.700 16 60 34011 31.000 – 1.100 16 60 34005 1.700 – 1.800 16 60 34012 1.100 – 1.200 16 60 34006 1.800 – 1.900 16 60 34013 1.200 – 1.300 16 60 34007 1.900 – 2.000 16 60 34014 webcode WWZT7006 Hydrometers, Ludwig Schneider • Precision hydrometer “Made in Germany” for density measurement of liquids • Calibratable • With individual serial number Density hydrometers, range finder Ref. temperature: 20°C Measuring range g/cm3 Scale g/cm3 Overall length mm Order No. 1.000 – 2.000 0.01 300 10 16 53011 1.000 – 1.500 0.005 300 10 16 53014 Density hydrometers Measuring range g/cm3 Scale g/cm3 Overall length mm calibrateable version with factory test certificate with DAkkS calibration certificate Order No. Order No. Order No. 0.600 – 0.700 0.001 300 10 16 53021 10 16 55221 10 16 55321 0.700 – 0.800 0.001 300 10 16 51822 10 16 55222 10 16 55322 0.800 – 0.900 0.001 300 10 16 51823 10 16 55223 10 16 55323 0.900 – 1.000 0.001 300 10 16 51824 10 16 55224 10 16 55324 1.000 – 1.100 0.001 300 10 16 51825 10 16 55225 10 16 55325 1.100 – 1.200 0.001 300 10 16 51826 10 16 55226 10 16 55326 1.200 – 1.300 0.001 300 10 16 51827 10 16 55227 10 16 55327 1.300 – 1.400 0.001 300 10 16 51828 10 16 55228 10 16 55328 1.400 – 1.500 0.001 300 10 16 51829 10 16 55229 10 16 55329 1.500 – 1.600 0.001 300 10 16 51830 10 16 55230 10 16 55330 Measuring Systems Density and Concentration • Reference temperature: 20°C • Available with integrated thermometer (mercury-free) • Further measuring ranges (up to 4,000 g/cm3) available on request • Standard calibration (WPS & DAkkS) with 3 test points, additional test points available on request

RkJQdWJsaXNoZXIy MTIxNDc3OQ==