Catálogo General de Material para Laboratorio

976 Polarimeters 1 Article Order No. 1Polarimeter P3000 10 61 13000 2 Digital polarimeter P8000 series The polarimeters of the P8000 series are the fastest polarimeters in the world – thanks to the patented measuring method, which reduces the measuring time to approx. 1 s regardless of the sample’s angle of rotation. The P8000 instruments measure up to an optical density of 3.0 OD. They are used when particularly high demands are placed on measurement accuracy and on continuous data recording and data backup. The instruments have all the functions required in FDA-regulated areas and meet all requirements of GMP/GLP and international standards. Technical data: Scales: Optical rotation [°] Int. sugar scale [°Z] Concentration [g/100 ml] Spec. rotation User-defined Measurement range: ±90° ±259°Z Measurement accuracy: 0.001° 0.01°Z ml Measurement period ± 90°: approx. 1 s Light source: 1 LED with filter Wavelength: 589 nm Temperature measurement range: 0 – 99.9°C Temperature measurement resolution: 0.1°C Temperature measurement accuracy: ±0.2°C Type Measurement accuracy Equipment Order No. P8000 ±0.003° ±0.01°Z Without temperature control 63 61 80000 P8100 ±0.002° ±0.01°Z Without temperature control 10 61 18102 2P8000-T ±0.003° ±0.01°Z With circulation thermostat temperature control 10 61 18002 P8100-T ±0.002° ±0.01°Z With circulation thermostat temperature control 10 61 18103 P8000-TF ±0.003° ±0.01°Z With circulation thermostat temperature control 10 61 18003 P8100-TF ±0.002° ±0.01°Z With circulation thermostat temperature control 10 61 18104 P8000-P ±0.003° ±0.01°Z With Peltier temperature control 10 61 18004 P8100-P ±0.002° ±0.01°Z With Peltier temperature control 10 61 18105 T-versions in addition with water specimen temperature control TF-versions in addition with water specimen temperature control and flow function Polarimeter P3000 The polarimeter P3000 is based on the technology of the P8000 series but built for standard applications for which a measurement accuracy of ±0.01° is sufficient and a temperature control can be omitted. Typically, the P3000 is used in the quality control of food industry. Like the P8000 models this model performs the record measuring time of approx. 1 second. The P3000 measures up to an optical density of 3.0 OD. Technical data: Scales: Optical rotation [°] Int. sugar scale [°Z] Measurement range: ±90° ±259°Z Measurement accuracy: ±0.01° ±0.01°Z Resolution: 0.01° 0.01°Z Measurement period ±90°: Approx. 1 s Light source: 1 LED with filter Wavelength: 589 nm Temperature measurement: 0 – 99.9°C Optical Investigations Spectroscopy

RkJQdWJsaXNoZXIy MTIxNDc3OQ==