To see other variants and accessories, please enter the webcode on our website. webcode 993 Electronic Controllers 2 3 4 3TEMPAT®-DSI temperature controller Configuration same as TEMPAT®-D, except with additional integrated 2-pole irreversible excess temperature or probe breakdown safety shutoff. Fault lamp and warning signal, re-start button, second sensor input jack, potentiometer for setting the threshold temperature and monitoring on LED display. Rating: 1800 W 8 A. Option for all 3 TEMPAT® controllers: recorder output available for 0 – 20 mA, 0 – 1 V or 0 – 10 V. The scope of delivery of TEMPAT® controllers does not include feelers. For temperature feelers that match and are ready for connection, see accessories. If no temperature feeler was ordered, the connection plug suitable for the device is loosely attached. Sensor type Temperature range °C Order No. Pt 100 0 – 400 71 65 50280 Fe-CuNi 0 – 600 71 65 50281 NiCr-Ni 0 – 1200 71 65 50282 4TEMPAT®-DSI temperature controller Safety temperature switch for monitoring all kinds of temperature control tasks. Ideal for complementing simple temperature controllers. Very suitable for monitoring the temperature of heating tapes, heating mantles, water baths and other heaters which are prone to failure of a switch element and to temperature increases to prohibited high ranges. Simple operation: plug heater which is to be monitored in the output plug of TEMPAT®- Control, place feeler in the spot which is to be monitored. Set desired temperature limit on the scale. The device now monitors the connected heater. If the set temperature limit is exceeded, the device turns off the connected heater. An optical and acoustic alarm is triggered, which continues even if the temperature falls below the set temperature limit. For reconnection, press reset key. Rating: 1800 W 8 A. Sensor type Temperature range °C Order No. Pt 100 0 – 600 10 65 50290 Fe-CuNi 0 – 700 10 65 50291 NiCr-Ni 0 – 1300 10 65 50292 5 5Accessories Sensors for TEMPAT®, TEMPAT®-D, TEMPAT®-DSI controllers and TEMPAT®- Control Article Order No. Resistance probe Pt 100 71 65 50121 4301 stainless steel sensor tube, 3.0 mm dia., 250 mm long, with 2 m cable and connector, 3-wire Resistance probe Pt 100 71 65 50100 as above, except 2.0 mm dia., 2-wire Resistance probe Pt 100 71 65 50101 as above, except 1.6 mm dia., 2-wire Resistance probe double PT 100 10 65 50161 as above, except 3.0 mm dia., 2-wire Glass probe Pt 100 71 65 50131 4.3 mm dia., 35 mm long, with 2 m cable and connector, 2-wire Glass probe Pt 100 10 65 50171 as above, except 3.0 mm dia., 250 mm long, 2-wire for all temperature controllers TEMPAT/TEMPAT-D/TEMPAT-DSI/TEMPAT-Control Thermocouple Fe-CuNi 71 65 50141 austenitic stainless steel jacket, 1.5 mm Ø, 250 mm long, with 2 m compensation line and connector Thermal sensor NiCr-Ni, Ø 1.5 mm 71 65 50151 Inconel jacket, otherwise as above Thermal sensor NiCr-Ni, Ø 1.5 mm 10 65 50181 100 mm long, otherwise as above Other diameters and lengths on request. Other self-optimizing temperature controllers with digital display of nominal and actual values: TEMPAT®3000 MCS and MCSI series, and TEMPAT®3000 MPR series program controllers with various options on request. Control Equipment, Evaluation Equipment Electronic Controllers
RkJQdWJsaXNoZXIy MTIxNDc3OQ==